Specialist home inspections: the InspectOS Pro modules
An InspectOS Pro module is the tool for one specialist inspection, with its own sections. Each module opens only for a technician qualified in that field. The modules below match services you can book today.
InspectOS Pro is rolling out in phases. Some capabilities described below are still being built.
Method or module
The method serves general and pre-purchase inspections. A module serves one specialist inspection, with sections and fields of its own. See the method
Each module opens for the engineer with the approved qualification for that field. Each module's report comes from the fields the engineer fills in on site.
Which service uses each module, and why
- Gas
The gas module follows the installation from the meter to the flue: pipework, shutoff valves, appliances and ventilation. Under Decreto-Lei n.º 97/2017, an installation over 10 years old and not remodelled is inspected every 5 years.
8 sections: Property Identification · Gas Supply & Metering · Internal Piping Network · Shutoff Valves · Gas Appliances · Ventilation · Flue Gas Evacuation · Site Observations
Used for: the gas inspection, gas in condominium buildings
- Energy
The energy module records the envelope, the glazing, ventilation, heating, cooling, hot water and renewable energy. These are the data that set the home's energy class.
9 sections: Property Identification · Building Envelope · Glazing & Windows · Ventilation · Heating System · Cooling System · Domestic Hot Water (AQS) · Renewable Energy · Site Observations
Used for: the home's energy certificate, the renovation passport
Who fills it in: SCE Qualified Expert, registered with ADENE
- Structural and seismic
The structural and seismic module identifies the structural system, rates the condition of each element and records irregularities and non-structural risks. It closes with the seismic risk assessment and recommendations.
9 sections: Project & Building Information · Applicable Seismic Codes & Standards · Site & Soil Conditions · Structural System Identification · Structural Element Condition · Non-Structural Components Risk · Structural Irregularities & Vulnerabilities · Seismic Evaluation Method & Analysis · Final Seismic Risk Assessment & Recommendations
Used for: the structural and seismic assessment
Who fills it in: Civil engineer registered with the Ordem dos Engenheiros (OE)
- Moisture
The moisture module works from the outside in: entry points outside, signs of damp and mould inside, measurements, ventilation, and the type of damp with its likely source. It closes with risk, history and recommendations.
13 sections: Basic Building Information · Building Characteristics · External Moisture Ingress Points · Internal Signs of Damp & Mould · Moisture Measurements & Profiling · Ventilation, Humidity & Environment · Types of Damp & Moisture Sources · Timber & Material Defects · Structural & Building Defects · History & Previous Interventions · Risk Assessment & Impacts · Inspections & Methods Used · Safety, Recommendations & Remediation
Used for: the moisture inspection
Which module answers which problem
Start from what you see in the home. Each row names the module and the sections where the engineer records the answer.
Stains, mould or a musty smell, and you do not know where the water comes from
Moisture: External Moisture Ingress Points · Internal Signs of Damp & Mould · Types of Damp & Moisture Sources
New finishes already failing after a renovation
Moisture: Timber & Material Defects · History & Previous Interventions
Cracks in walls or beams, or an older building about to undergo works
Structural and seismic: Structural Element Condition · Structural Irregularities & Vulnerabilities
Knowing how the building's structure behaves in an earthquake
Structural and seismic: Structural System Identification · Final Seismic Risk Assessment & Recommendations
A home that is cold in winter or hot in summer
Energy: Building Envelope · Glazing & Windows
Understanding what weighs on the home's energy class
Energy: Heating System · Cooling System · Domestic Hot Water (AQS)
Frequently asked questions
- What is the difference between the method and a module?
- The method is the fixed list for the general and pre-purchase inspection. A module is the tool for one specialist inspection, such as gas or energy, with its own sections and more detail in one field.
- Who can fill in a module?
- Only a technician qualified in that field. A module opens once the InspectOS team has checked the qualification, such as qualified expert for energy, or civil engineer with the Ordem dos Engenheiros for seismic work.
- Which specialist inspection should I book?
- The one that matches the problem or the obligation. Active damp calls for the moisture inspection; a gas installation over 10 years old, the gas inspection; a home whose energy certificate has expired, the energy certificate.