This website uses limited-risk AI systems in compliance with the European AI Regulation (EU AI Act). Compliance monitoring features are supervised by qualified professionals.

Finding the source of damp: the InspectOS Pro moisture module

The InspectOS Pro moisture module traces damp from where water gets in to its likely source, in thirteen steps. It combines visible signs, readings and the building's history. The methods and equipment used are described on the service page.

InspectOS Pro is rolling out in phases. Some capabilities described below are still being built.

Moisture module on the measurements and profiling step
The measurements step in the moisture module. Tap to enlarge.

What the engineer records, section by section

Every field below is in the module, as the engineer fills it in on site.

  1. 01Basic Building Information

    • Type of buildingApartment · House · Commercial · Basement / Garage · Other
    • Type of constructionConcrete · Brick · Stone · Timber frame · Solid wall · Cavity wall · Mixed
    • Type of ownershipOwner · Tenant · Rental property · Social housing
    • Year of Construction
    • Building Area (m²)
    • Number of Floors Affected
    • Elevation / Flood riskLow risk · Medium risk · High / flood zone · Unknown
  2. 02Building Characteristics

    • Wall materialsBrick · Stone · Concrete block · Sand/cement render · Lime render · Porous masonry · Non-porous cladding
    • DPC (Damp Proof Course) present?Yes – physical DPC · Yes – chemical injection · No DPC · Unknown
    • DPC conditionIntact / functioning · Bridged or bypassed · Failed / degraded · Cannot determine
    • Floor construction typeSolid concrete slab · Suspended timber · Beam & block · Mixed
    • Roof constructionPitched – tiles · Pitched – slate · Flat roof membrane · EPDM / felt flat · Green roof
    • Glazing typeSingle glazed · Double glazed · Triple glazed · Mixed
    • Ground level vs internal floorExternal lower (normal) · External at same level · External higher (bridging risk)
    • Subfloor ventilationAdequate grilles – clear · Grilles present – blocked · No grilles / vents · N/A (solid floor)
    • Wall thickness<200mm (thin) · 200–300mm · 300–500mm (solid) · >500mm (thick stone)
  3. 03External Moisture Ingress Points

    • Roof conditionGood – no defects · Missing/broken tiles · Defective flashings · Chimney pointing failed · Valley defects · Active leak confirmed
    • Gutters & downpipesClear and functioning · Blocked gutters · Leaking joints · Overflowing · Downpipe discharging near wall · Missing sections
    • External wall defectsNo defects · Failed pointing · Render cracks · Masonry spalling · No waterproofing · Crack at DPC level
    • Window & door junctionsAll sealed – good · Failed seals/beading · Missing sill or drip · Cracked lintels · Defective flashing at head
    • Landscaping & site drainageGround slopes away – good · Ground slopes toward building · Standing water observed · Paved area causing bridging · Soil raised above DPC
    • External plumbing issuesNo issues · Known pipe burst history · Suspected leak · Drainage failure
  4. 04Internal Signs of Damp & Mould

    • Visible signs presentTide marks / staining · Black mould · Green/white mould · Peeling paint/plaster · Efflorescence (salt deposits) · Musty odour · No visible signs
    • Locations / rooms affectedGround floor walls – base · Upper wall areas · Ceiling · Floor surface · Skirtings · Corners · Behind furniture · Bathroom/kitchen · Basement/cellar
    • Condensation evidenceNone observed · On windows · On cold pipes · On cold wall surfaces · On ceilings
    • Timber decay / insect activityNone · Wet rot · Dry rot · Fungal growth · Active woodworm · Inactive woodworm
    • Internal flooding / pooling historyNo history · Single event · Recurring events · Currently affected
  5. 05Moisture Measurements & Profiling

    • Moisture meter type usedPin meter · Non-invasive / RF meter · Both · Not used
    • Moisture content (MC%) readings at base of wallDry (<10%) · Slightly damp (10–15%) · Damp (15–20%) · Very wet (>20%) · Not measured
    • Height profile of moisture rise<300mm (very low) · 300–600mm · 600mm–1m · >1m (high rise) · Uniform (not rising damp) · Not measured
    • Relative Humidity (%RH) measuredBelow 60% – acceptable · 60–70% – elevated · 70–80% – high · >80% – very high · Not measured
    • Hygrometer / moisture surveyPerformed – no anomalies · Performed – cold bridges found · Performed – hidden moisture found · Not performed
    • Hygroscopic/salt analysis performed?Yes – negative (no significant salts) · Yes – positive (nitrates detected) · Yes – positive (chlorides detected) · Yes – high levels (lab confirmed) · Not performed
  6. 06Ventilation, Humidity & Environment

    • Type of ventilation presentNatural – openable windows · Mechanical extractor fans · Trickle vents in frames · Subfloor air bricks · MVHR (heat recovery) · PIV (positive input) · No ventilation
    • Ventilation effectivenessAdequate · Partially adequate · Inadequate · Very poor / none
    • Indoor humidity sourcesHigh occupancy · Cooking without extraction · Showering without extraction · Drying clothes indoors · Many houseplants · Fish tanks / humidifiers · Low occupancy / minimal sources
    • Hours at home / occupancy patternAll day (high exposure) · Most of day · Evenings/weekends only · Mostly unoccupied
    • Dew point / condensation risk levelLow risk (<55% RH, warm surfaces) · Moderate risk (55–65% RH) · High risk (>65% RH, cold surfaces) · Not assessed
  7. 07Types of Damp & Moisture Sources

    • Primary damp type(s) identifiedCondensation · Rising damp · Penetrating damp · Plumbing leak · Construction moisture · Hygroscopic salts · Interstitial condensation · Flood damage
    • Confidence in diagnosisHigh – clear evidence · Medium – probable · Low – uncertain, needs further investigation
    • Rising damp indicators (if applicable)Tide marks on lower walls · Salt deposits at low level · Moisture tapers from base upward · DPC absent/failed · N/A
    • Penetrating damp indicators (if applicable)Damp at window reveals · Damp below roof line · Localised patch after rain · Damp at chimney breast · N/A
  8. 08Timber & Material Defects

    • Timber condition (skirtings, joists, floorboards)Sound – no defects · Surface staining only · Wet rot present · Dry rot present · Fungal strands observed · Structural compromise
    • Insect infestationNone · Active woodworm · Inactive woodworm · Termites · Other
    • Insulation conditionGood – dry and intact · Wet / saturated · Compressed and degraded · Mouldy · Not present / N/A
    • Floor coverings conditionDry and sound · Damp under carpet · Damp under vinyl/laminate · Underlay saturated · Lifting / bubbling
    • Timber MC% readingsDry (<18%) · Slightly elevated (18–20%) · At risk (20–25%) · Wet rot risk (>25%) · Not measured
  9. 09Structural & Building Defects

    • Cracks observedNo cracks · Hairline cracks – cosmetic · Diagonal cracks – settlement · Horizontal cracks – structural concern · Vertical cracks · Active (widening) · Historic (stable)
    • Crack width<1mm (fine) · 1–5mm (moderate) · 5–15mm (wide – concern) · >15mm (severe) · N/A – no cracks
    • Subsidence / settlement signsNone observed · Minor – monitoring advised · Suspected – investigation needed · Active subsidence
    • Chimney / fireplace defectsNo defects / N/A · Damp at chimney breast · Salt deposits at breast · Capping absent · Failed flashing
    • Other structural concernsNone · Blocked cavity wall · Wall tie failure suspected · Service penetrations (unsealed) · Foundation damp-proofing visible failure
  10. 10History & Previous Interventions

    • Previous damp treatmentsNo previous treatments · Chemical DPC injection · Membranes / tanking · Waterproof renders · Timber treatment · Drainage / sump
    • Prior survey / guaranteeYes – recent (within 5 years) · Yes – older · Guarantee in place · No prior survey
    • Previous mould remediationNone · Surface cleaning · Dry fogging · Ventilation upgrade · Material removal
    • Maintenance historyRegular maintenance · Roof repairs done · Gutter cleaning done · Re-rendering done · Plumbing fixes done · No maintenance
  11. 11Risk Assessment & Impacts

    • Overall severity rating🟢 Low · 🟡 Medium · 🟠 High · 🔴 Severe
    • Estimated extent of affected surfaces<5m² (minor) · 5–20m² (moderate) · 20–50m² (significant) · >50m² (extensive)
    • Health & safety risks identifiedMould spore exposure · Respiratory risk · Allergic / asthma risk · Dust mites · VOCs from mould · Slip risk (wet floors) · Minimal health risk
    • Vulnerable occupants present?Children · Elderly · Asthma / respiratory · Immunocompromised · None / unknown
    • Structural risk levelNo structural risk · Timber weakening risk · Material degradation ongoing · Active structural concern
    • Urgency of actionMonitor only · Within 3–6 months · Within 1 month · Immediate action required
  12. 12Inspections & Methods Used

    • Inspection methods performedVisual inspection · Moisture profiling (pin) · Moisture profiling (non-invasive) · Moisture mapping · Hygrometer / dew point · Salt analysis · Laboratory testing · Borescope / endoscope · Airborne spore sampling · Photographic log · Client remote intake
    • DPC / damp-proof membrane inspectionInspected – adequate · Inspected – defective · Inspected – absent · Not accessible
    • Photographic / video evidence qualityComprehensive · Partial · Minimal · None
  13. 13Safety, Recommendations & Remediation

    • Recommended remediation actions
    • Specialist referrals neededNone required · Structural engineer · Waterproofing specialist · Timber specialist · Plumber · Building surveyor · Environmental health
    • Long-term prevention measuresAnnual monitoring plan · Breathable materials · Lifestyle advice · Regular maintenance · Hygrometer installation · Building fabric upgrade

What the law says

  • In a private sale, the buyer reports a defect within 1 year of discovering it and sues within 6 months of the report, all within 5 years of delivery. The burden of proof is on the buyer. (Código Civil, arts. 916.º, 917.º, 342.º n.º 1)
  • When a professional sells a home to a consumer, Decreto-Lei n.º 84/2021 gives 10 years for structural defects and 5 years for others. (DL 84/2021, art. 23.º n.º 1)

What our engineers found

  • Water getting in from outside was the cause of damp InspectOS engineers recorded most often, in 66% of 2026 moisture inspections. It points to the building envelope: roofs, terraces, facades, window frames and walls against the ground.
  • Condensation was never the only cause: wherever it was recorded, another source of water was present as well.
  • In 14% of 2026 damp inspections, engineers found active moisture at spots that had already been repaired or repainted.

What this means for you: Fresh paint over a damp patch is not a repair. Ask the seller what caused the damp and what work was done.

From the InspectOS 2026 inspection data, a random sample of our inspections.See the 2026 inspection data

Guides to read next

Frequently asked questions

How do you tell rising damp, water ingress and condensation apart?
Rising damp comes up from the ground and marks the lower part of walls, often with salt deposits. Water ingress gets in through the roof, facade or window frames and gets worse after rain. Condensation forms on cold surfaces, in corners and on glass, mostly in winter.
Why does painting over damp not fix it?
Because water keeps arriving from the same source. The paint hides the stain for a while and the problem comes back. The module follows the water from where it gets in to its likely source, so the fix deals with the cause.
I found damp after buying. Can I still claim?
In a private sale, you report the defect within 1 year of discovering it, within 5 years of delivery. If the seller is a professional, DL 84/2021 gives 10 years for structural defects and 5 for others. A report that identifies the source helps prove the defect.

Book the visit

Book Inspection