This website uses limited-risk AI systems in compliance with the European AI Regulation (EU AI Act). Compliance monitoring features are supervised by qualified professionals.

What the expert records for an energy certificate: InspectOS Pro module

The InspectOS Pro energy module collects on site the data a qualified expert needs for the energy certificate. It has nine sections, from the building envelope to renewable energy. The same module serves the renovation passport.

InspectOS Pro is rolling out in phases. Some capabilities described below are still being built.

What drives an energy class

An energy class compares the home's energy needs, for heating, cooling and hot water, with a reference value. Each factor below moves those needs, and the module records it in a field of its own.

Location and size

The winter climate zone, from I1 to I3, sets how much cold the home has to overcome. Orientation changes solar gains, and floor area and typology shape hot-water needs.

Fields in the module: District · Climate Zone · Year Built · Typology · Floor Area (m²) · Orientation · Floor Level · Number of Floors

Walls and roof

Walls and roof lose heat in winter and gain it in summer. The U-value measures that flow: the lower it is, the better the element insulates. Wall type and insulation thickness set it.

Fields in the module: Wall Type · Wall U-Value · Roof Type · Roof U-Value · Wall Insulation Thickness (cm) · Roof Insulation Thickness (cm)

Windows

A window lets more heat through than an insulated wall. Glazing type, frame and glazed area set the losses, and blinds cut summer heat gain.

Fields in the module: Glazing Type · Total Glazing Area (m²) · With blinds · Frame Type

Ventilation

Every air change swaps heated air for outside air. Air permeability shows how leaky the home is, and heat recovery returns part of the heat in the outgoing air.

Fields in the module: Ventilation Type · Air Change Rate (Rph) · Air Permeability · Heat Recovery

Heating, cooling and hot water

The same need takes less energy with a more efficient system. A heat pump delivers more heat than the electricity it uses. Tank insulation and a programmable thermostat cut losses further.

Fields in the module: Heating System · Installed Power (kW) · Programmable Thermostat · Cooling System · Cooling Capacity (kW) · External Shading · DHW System · Tank Volume (L) · Tank Insulation · Solar Thermal

Renewable energy

Energy produced at the home, by photovoltaic panels or solar thermal collectors, offsets part of its needs. Installed area and power set how much.

Fields in the module: PV Panels · PV Panel Area (m²) · PV Power (kWp) · Self-consumption · Solar Thermal DHW · Collector Area (m²)

What this means for a buyer

A low class points to uninsulated walls or roof, single glazing or inefficient systems. Read the certificate with these fields in mind: they show where the home loses energy.

In the pre-purchase inspection, section B of the method records wall and roof insulation and thermal bridges. See damp and insulation

What the engineer records, section by section

Every field below is in the module, as the engineer fills it in on site.

  1. 01Property Identification

    • District
    • Climate Zone
    • Year Built
    • Typology
    • Floor Area (m²)
    • Orientation
    • Floor Level
    • Number of Floors
  2. 02Building Envelope

    • Wall Type
    • Wall U-Value
    • Roof Type
    • Roof U-Value
    • Wall Insulation Thickness (cm)
    • Roof Insulation Thickness (cm)
  3. 03Glazing & Windows

    • Glazing Type
    • Total Glazing Area (m²)
    • With blinds
    • Frame Type
  4. 04Ventilation

    • Ventilation Type
    • Air Change Rate (Rph)
    • Air Permeability
    • Heat Recovery
  5. 05Heating System

    • Heating System
    • Installed Power (kW)
    • Programmable Thermostat
  6. 06Cooling System

    • Cooling System
    • Cooling Capacity (kW)
    • External Shading
  7. 07Domestic Hot Water (AQS)

    • DHW System
    • Tank Volume (L)
    • Tank Insulation
    • Solar Thermal
  8. 08Renewable Energy

    • PV Panels
    • PV Panel Area (m²)
    • PV Power (kWp)
    • Self-consumption
    • Solar Thermal DHW
    • Collector Area (m²)
  9. 09Site Observations

    • General Observations
    • Technical Constraints
    • Visual Inspection Done

Who fills it in

SCE Qualified Expert, registered with ADENE

What the law says

  • Under Decreto-Lei n.º 101-D/2020, an energy certificate is valid for 10 years, or 8 for large commercial and service buildings. (DL 101-D/2020, art. 23.º)
  • Fines run from €250 to €3,740 for individuals and from €2,500 to €44,890 for companies. (DL 101-D/2020, art. 35.º n.º 1)
  • They are applied by the câmara municipal (new builds and renovations) or by DGEG (owners, estate agents and advertisers), not by ADENE. (DL 101-D/2020, art. 37.º)

Guides to read next

Frequently asked questions

How long is an energy certificate valid?
10 years, or 8 for large commercial and service buildings (DL 101-D/2020, art. 23).
What does the expert need to see during the visit?
The envelope, glazing and windows, ventilation, heating, cooling, hot water and renewables. It helps to have the equipment invoices or labels to hand, and details of any insulation work done.
Who applies energy certificate fines?
The câmara municipal for new builds and renovations, or DGEG for owners, estate agents and advertisers. It is not ADENE (DL 101-D/2020, art. 37).

Book the visit

Book Inspection