What the expert records for an energy certificate: InspectOS Pro module
The InspectOS Pro energy module collects on site the data a qualified expert needs for the energy certificate. It has nine sections, from the building envelope to renewable energy. The same module serves the renovation passport.
InspectOS Pro is rolling out in phases. Some capabilities described below are still being built.
What drives an energy class
An energy class compares the home's energy needs, for heating, cooling and hot water, with a reference value. Each factor below moves those needs, and the module records it in a field of its own.
Location and size
The winter climate zone, from I1 to I3, sets how much cold the home has to overcome. Orientation changes solar gains, and floor area and typology shape hot-water needs.
Fields in the module: District · Climate Zone · Year Built · Typology · Floor Area (m²) · Orientation · Floor Level · Number of Floors
Walls and roof
Walls and roof lose heat in winter and gain it in summer. The U-value measures that flow: the lower it is, the better the element insulates. Wall type and insulation thickness set it.
Fields in the module: Wall Type · Wall U-Value · Roof Type · Roof U-Value · Wall Insulation Thickness (cm) · Roof Insulation Thickness (cm)
Windows
A window lets more heat through than an insulated wall. Glazing type, frame and glazed area set the losses, and blinds cut summer heat gain.
Fields in the module: Glazing Type · Total Glazing Area (m²) · With blinds · Frame Type
Ventilation
Every air change swaps heated air for outside air. Air permeability shows how leaky the home is, and heat recovery returns part of the heat in the outgoing air.
Fields in the module: Ventilation Type · Air Change Rate (Rph) · Air Permeability · Heat Recovery
Heating, cooling and hot water
The same need takes less energy with a more efficient system. A heat pump delivers more heat than the electricity it uses. Tank insulation and a programmable thermostat cut losses further.
Fields in the module: Heating System · Installed Power (kW) · Programmable Thermostat · Cooling System · Cooling Capacity (kW) · External Shading · DHW System · Tank Volume (L) · Tank Insulation · Solar Thermal
Renewable energy
Energy produced at the home, by photovoltaic panels or solar thermal collectors, offsets part of its needs. Installed area and power set how much.
Fields in the module: PV Panels · PV Panel Area (m²) · PV Power (kWp) · Self-consumption · Solar Thermal DHW · Collector Area (m²)
What this means for a buyer
A low class points to uninsulated walls or roof, single glazing or inefficient systems. Read the certificate with these fields in mind: they show where the home loses energy.
In the pre-purchase inspection, section B of the method records wall and roof insulation and thermal bridges. See damp and insulation
What the engineer records, section by section
Every field below is in the module, as the engineer fills it in on site.
01Property Identification
- District
- Climate Zone
- Year Built
- Typology
- Floor Area (m²)
- Orientation
- Floor Level
- Number of Floors
02Building Envelope
- Wall Type
- Wall U-Value
- Roof Type
- Roof U-Value
- Wall Insulation Thickness (cm)
- Roof Insulation Thickness (cm)
03Glazing & Windows
- Glazing Type
- Total Glazing Area (m²)
- With blinds
- Frame Type
04Ventilation
- Ventilation Type
- Air Change Rate (Rph)
- Air Permeability
- Heat Recovery
05Heating System
- Heating System
- Installed Power (kW)
- Programmable Thermostat
06Cooling System
- Cooling System
- Cooling Capacity (kW)
- External Shading
07Domestic Hot Water (AQS)
- DHW System
- Tank Volume (L)
- Tank Insulation
- Solar Thermal
08Renewable Energy
- PV Panels
- PV Panel Area (m²)
- PV Power (kWp)
- Self-consumption
- Solar Thermal DHW
- Collector Area (m²)
09Site Observations
- General Observations
- Technical Constraints
- Visual Inspection Done
Who fills it in
SCE Qualified Expert, registered with ADENE
What the law says
- Under Decreto-Lei n.º 101-D/2020, an energy certificate is valid for 10 years, or 8 for large commercial and service buildings. (DL 101-D/2020, art. 23.º)
- Fines run from €250 to €3,740 for individuals and from €2,500 to €44,890 for companies. (DL 101-D/2020, art. 35.º n.º 1)
- They are applied by the câmara municipal (new builds and renovations) or by DGEG (owners, estate agents and advertisers), not by ADENE. (DL 101-D/2020, art. 37.º)
Guides to read next
Frequently asked questions
- How long is an energy certificate valid?
- 10 years, or 8 for large commercial and service buildings (DL 101-D/2020, art. 23).
- What does the expert need to see during the visit?
- The envelope, glazing and windows, ventilation, heating, cooling, hot water and renewables. It helps to have the equipment invoices or labels to hand, and details of any insulation work done.
- Who applies energy certificate fines?
- The câmara municipal for new builds and renovations, or DGEG for owners, estate agents and advertisers. It is not ADENE (DL 101-D/2020, art. 37).
Book the visit
- Energy Performance Certificate
from 400 €
Book - Renovation Passport
from 2,950 €
Book